Information Exchange Manager (IEM) Server Requirements (Rack Mount Ready - 2U)

Processor:
Dual X5550 Xeon Processor, 2.66GHz 8M Cache, Turbo, HT
Memory:
6GB Memory (6x1GB), 1333MHz Single Ranked UDIMMs for 2 Processors, Optimized
Hard Drives:
2x146 GB, 15K RPM, Serial-Attach SCSI 3.5 inch Hot Plug Hard Drive - (for system with no Medical Oncology Faxing or Scanning Interfaces)
or
2x450 GB, 15K RPM, Serial-Attach SCSI 3.5 inch Hot Plug Hard Drive - (for system with Medical Oncology Faxing or Scanning interfaces)
Drive Controller:
• Internal PERC 6/i Dual Channel SAS 3.0 GB/s RAID[3] controller with 256 MB of battery-backed cache.
• Configure 2x146GB OS/APP (RAID 1) - (for system with no Medical Oncology Faxing or Scanning Interfaces); or
• Configure 2x450GB OS/APP (RAID 1) - (for system with Medical Oncology Faxing or Scanning Interfaces)
• DVD operates from SATA CONTROLLER ON BOARD
Floppy Disk:
None
Optical Drive:
Internal Slim optical DVD + RW
Network Adapter:
Dual Two-Port Embedded Broadcom® NetXtreme II™ 5709 Gigabit Ethernet NIC.
Redundancy:
PSU and Fans
Ports:
minimum 2 USB
Operating System:
Microsoft® Windows® Server 2003 Standard Edition (English version only), with Service Pack 2; (5 client access licenses or sufficient seat licenses)
File System:
NT File System (NTFS)
Partition C: Partition D:
With no Medical Oncology Faxing or Scanning interfaces 30 GB 116GB
With Medical Oncology Faxing or Scanning interfaces 30 GB 420GB
Microsoft® OS Architecture:
32-bit (not 64-bit)

Notes:

  1. CPU identified above is for Intel®'s Nehalem (microarchitecture). Each CPU has three separate memory controller hubs (MCHs) within the CPU package, and requires each memory channel to be populated per CPU for optimal use.
  2. Virtualization of the IEM Server is currently not available or supported.
  3. Software RAID is neither recommended nor supported with the IEM Server.
  4. If the customer is providing a filtered data feed, one IEM Server can normally support up to about 150 concurrent users. If there is a substantial amount of filtering required in the IEM Server, fewer concurrent users may be supported on one interface engine. Another parameter to evaluate is the number of messages per day. If there is a need to parse in excess of about 50,000 messages a day, additional IEM Servers may be needed.
  5. Hardware used with IEM must be approved based on the current Microsoft® specifications.
  6. 1 Gbps network recommended for maximum speed and performance.
  7. Specifications subject to change without notice as newer computer models become available.

 

Contact Varian Oncology

Varian Oncology Headquarters
Tel: 1.650.424.5700
Contact Us

Events